What Our Customers Are Saying
| Product type | Actuator |
| IP rating | IP66 |
| Manufacturer | Belimo |
| Power Supply | 24Vac/Vdc |
| Torque | 6 Nm |
| Running time | Quick (2.5 to 20 sec) |
NKQ24P-1 POP Damper Actuator, 6 Nm, AC/DC 24 V, 4 s
Fields of application: The actuator is particularly suitable for utilisation in outdoor applications and is protected against the following weather conditions: Wood drying, animal breeding, food processing, agricultural, swimming baths / bathrooms, rooftop ventilation plant rooms, general outdoor applications, changing atmosphere and laboratories.
Resistances: Noxious gas test EN 60068-2-60 (Fraunhofer Institut ICT / DE) Salt fog spray test EN 60068-2-52 (Fraunhofer Institut ICT / DE) Ammoniac test DIN 50916-2 (Fraunhofer Institut ICT / DE) Climate test IEC60068-2-30 (Trikon Solutions AG / CH) Disinfectant (animals) (Trikon Solutions AG / CH) UV Test (Solar radiation at ground level) EN 60068-2-5, EN 60068-2-63 (Quinel / Zug CH)
Used materials: Actuator housing polypropylene (PP), Cable glands / hollow shaft polyamide (PA), Connecting cable FRNC, Clamp / screws in general Steel 1.4404, Seals EPDM and Form fit insert aluminium anodised
Mode of operation: The actuator moves the damper to the desired operating position at the same time as the integrated capacitors are charged. Interrupting the supply voltage causes the damper to be rotated back into the emergency setting position (POP) by means of stored electrical energy.
Pre-charging time (start up): The capacitor actuators require a pre-charging time. This time is used for charging the capacitors up to a usable voltage level. This ensures that, in the event of an electricity interruption, the actuator can move at any time from its current position into the preset emergency setting position (POP). The duration of the pre-charging time depends mainly on how long the power was interrupted.

Delivery condition (capacitors): The actuator is completely discharged after delivery from the factory, which is why the actuator requires approximately 20 s pre-charging time before initial commissioning in order to bring the capacitors up to the required voltage level.
Simple direct mounting: Simple direct mounting on the damper spindle with an universal spindle clamp, supplied with an anti-rotation device to prevent the actuator from rotating.
Manual override: Manual control with push-button possible - temporary. The gear is disengaged and the actuator decoupled for as long as the button is pressed.
High functional reliability: The actuator is overload protected, requires no limit switches and automatically stops when the end stop is reached.
Adjustable angle of rotation: Adjustable angle of rotation with mechanical end stops. A minimum permissible angle of rotation of 30° must be allowed for.
Home position: The first time the supply voltage is switched on, i.e. at the time of commissioning, the actuator carries out an adaption, which is when the operating range and position feedback adjust themselves to the mechanical setting range. The detection of the mechanical end stops enables a gentle approach to the end positions, thus protecting the actuator mechanics. The actuator then moves into the position defined by the positioning signal.
Direction of rotation switch: When actuated, the direction of rotation switch changes the running direction in normal operation. The direction of rotation switch has no influence on the emergency setting position (POP) which has been set.
Adaption and synchronisation: An adaption can be triggered manually by pressing the “Adaption” button. Both mechanical end stops are detected during the adaption (entire setting range). Automatic synchronisation after pressing the gear disengagement button is configured. The synchronisation is in the home position (0%). The actuator then moves into the position defined by the positioning signal.
Emergency setting position (POP) rotary knob: The «Emergency setting position» rotary knob can be used to adjust the desired emergency setting position (POP) between 0 and 100% in 10% increments. The rotary knob allways refers to the adapted angle of rotation range. In the event of an electricity interruption, the actuator will move into the selected emergency setting position (POP).
Electrical data:
Functional data:
Safety:
Weight: Approx. 2.3 kg
Terms Abbreviations: POP = Power off position / emergency setting position PF = Power fail delay time / bridging time