The Belimo SH24A-SR200 is a type of Actuator used in HVAC and ventilation systems.
The force applied by the Torque of the SH24A-SR200 is 450 N.
This Rotary Actuator needs to be supported by a power supply of 24Vac/Vdc.
IACS has the best prices on the right Belimo Actuators for your system.
Consult the Belimo custom datasheet above or contact iacs via email for personalised assistance if you have queries about size or installation.
SH24A-SR200 - Linear actuator with rack
• 450 N, 150 s / 100 mm / constant,
• AC /DC 240 V, modulating
• Stroke range 0...200 mm
• IP 54, Manual override by means of push-button
• Control DC 0...10 V
• Operating range DC 2...10 V for stroke 0...200 mm
• Position feedback DC 2...10 V
• Connection PVC cable 1m
Features
• Electrical data Nominal voltage AC 24 V, 50/60 Hz,DC 24 v
• Power supply range AC/DC 19.2 ... 28.8 V Power consumption In operation 2 W @ nominal force At rest0.4 W For wire sizing 4 VA
• Connection Power supply Cable 1 m, 2 x 0.75 mm2 Signals Cable 1 m, 3 x 0.75 mm2
• Functional data Actuating force 450 N @ nominal voltage
• Control Control signal Y DC 0 ... 10 V, typical input impedance 100 kΩ Operating range See «Overview of types»
• Position feedback (Measuring voltage U) DC 2 ... 10 V, max. 1 mA
• Position accuracy ±5%
• Stroke See «Overview of types»
• Direction of stroke at Y = 0 V Reversible with switch 1 resp. 0
• Running time 150 s / 100 mm
• Sound power level <50 dB (A)
• Safety Protection class II totally insulated
• Degree of protection IP54 in any mounting position NEMA 2, UL Enclosure Type 2
• EMC CE according to 2004/108/EC Low voltage directive CE according to 2006/95/EC
• Certification cULus according to UL 60730-1A and UL 60730-2-14 and CAN/CSA E60730-1:02 Certified to IEC/EN 60730-1 and IEC/EN 60730-2-14
• Mode of operation Type 1
• Rated impulse voltage Supply 0.8 kV Contro 0.8 kV
• Control pollution degree 3
• Ambient temperature range –30 ... +50°C
• Non-operating temperature –40 ... +80°C
• Ambient humidity range 95% r.H., non-condensating
• Maintenance Maintenance-free
• Dimensions / Weight Dimensions See «Dimensions» on page 3
• Weight See «Overview of types»