| Product type | Controller |
| IP rating | IP65 |
| Input Signal | NTC |
| Manufacturer | Carel |
| Power Supply | 230Vac, 1Ph, 50Hz |
| Parametric | Refrigeration Controllers |
| DIN/Panel Mounted | Panel Mounting |
This part number has replaced the PJ32C00000 which is now phased out
PJEZ* (models S, C, Y and X) represent a range of electronic microprocessor controllers with LED display developed for the management of refrigerating units, display cabinets and showcases.
Models PJEZS* are designed for the management of static refrigerating units (no fan on the evaporator) operating at temperatures above 0°C.
Models PJEZC* are designed for the management of low temperature ventilated refrigerating units.
Finally, models PJEZ(Y, X)* are designed for the management of static refrigerating units (no fan) operating at low temperatures.
Note: model Y= relays connected electronically internally; model X= independent relays.
| Technical specifications | |
| power supply (*) | 230 Vac +10 /-15% 50/60 Hz; 115 Vac +10 /-15% 50/60 Hz |
| rated power | 1,5 VA |
| inputs (*) | NTC or PTC probes 1 or 3 inputs. Digital input as alternative to third probe |
| relay outputs (*) | 2 HP relay UL: 12 to 12 FLA 72 LRA, EN60730-1: 10(10) A 250 Vac (**) 16 A relay UL: 14 A Res. EN60730-1: 14(2) A or 10(4) A (N.O. only) 5FLA, 30LRA 250 Vac, C300 8 A relay UL: 8 A Res. 2 FLA 12 LRA, EN60730-1: 6(2) A or 8(3) A (N.O. only) 5 A relay UL: 5 A Res. 1 FLA 6 LRA EN60730-1: 5(1) A |
| type of probe (*) | Std CAREL NTC 10 KΩ at 25 °C, Std CAREL PTC 985 Ω at 0 °C |
| connections (*) | screw terminals for cables with cross-sect. from 0.5 mm2 to 1.5 mm2. Plug-in terminals for screw blocks or with crimped contact (cable cross-sect. up to 2.5 mm2). Rated maximum current per terminal 12 A. |
| assembly (*) | terminal: using screws from the front panel or with rear brackets. Interface: wall mounting, 4 screws, spacing 101x151 mm |
| display | 3 digit LED display with sign (-199 to 999) and decimal point; six status LEDs |
| operating conditions | -10T50 °C - humidity <90% rH non-condensing |
| storage conditions | -20T70 °C - humidity <90% rH non-condensing |
| range of measurement | -50T90 °C (-58T194 °F) - resolution 0.1 °C/°F |
| front panel index of protection | panel installation with IP65 gasket |
| case | plastic terminal, 81x36x65 mm |
| classification according to protection against electric shock | Class II when suitably integrated |
| environmental pollution | normal |
| PTI of the insulating material | 250 V |
| period of stress across the insulating parts | long |
| category of resistance to heat and fire | category D (UL94 - V0) |
| immunity against voltage surges | category 1 |
| type of action and disconnection | 1C relay contacts |
| no. of relay automatic operating cycles (*) | EN60730-1: 6(2) A, 2(2) A, 5(1) A and 10(10) A: 100,000, 14(2) A: 30,000. UL: (250 Vac) 30,000 operations |
| software class and structure | Class A |
| cleaning the instrument | Only use neutral detergents and water. |