| IP rating | IP65 |
| Output Signal | 4..20 mA |
| Manufacturer | Belimo |
| Power Supply | 24Vac/Vdc |
| Sensor Type | Temperature and Humidity |
| Sensor characteristics | Duct Mounted |
| Probe Length | 50 mm |
Visit iacs to find every part of your HVAC system. In stock Belimo Humidity, CO2 Air Quality and Temperature Sensors may all be delivered with free delivery or 1-2 working days delivery.
The Belimo 22DTH-13M is a Sensor used in HVAC applications and it is a device that provides an precise measurement of Temperature and Humidity.
This type of Belimo Sensor 22DTH-13M is a solution used for duct measurement.
Find the best-priced Belimo Sensor that is compatible with your system at iacs.
If you have questions about size or installation, consult the Belimo custom datasheet above or send an email to iacs to get personal ised guidance.
| Electrical data | Power Supply DC | 15...24 V, ±10%, 0.5 W | ||||||||||||||||||||
| Electrical connection | Removable spring loaded terminal block max. 2.5 mm² | |||||||||||||||||||||
| Cable entry | cable gland PG11 Ø6...10 mm, with strain relief Ø6...8 mm | |||||||||||||||||||||
| Functional data | Sensor Technology | Polymer capacitive sensor with stainless steel wire mesh filter | ||||||||||||||||||||
| Multirange | YES | |||||||||||||||||||||
| Output signal active note | Current outout: max. 500 Ω load | |||||||||||||||||||||
| Media | Air | |||||||||||||||||||||
| Measuring data | Measured values | Temperature | ||||||||||||||||||||
| Humidity | ||||||||||||||||||||||
| Dew point | ||||||||||||||||||||||
| Enthalpies | ||||||||||||||||||||||
| Absolute humidity | ||||||||||||||||||||||
| Measuring range humidity | 0...100% rH non-condensing | |||||||||||||||||||||
| Measuring range temperature | range selectable | |||||||||||||||||||||
|
||||||||||||||||||||||
| Measuring range absolute humidity | adjustable at the transducer: | |||||||||||||||||||||
| 0...50 g/m³ (default setting) | ||||||||||||||||||||||
| 0...80 g/m³ | ||||||||||||||||||||||
| Measuring range enthalpy | 0...85 kJ/kg | |||||||||||||||||||||
| Measuring range dew point | adjustable at the transducer: | |||||||||||||||||||||
| 0...50 °C (default setting) | ||||||||||||||||||||||
| -20...80 °C | ||||||||||||||||||||||
| Accuracy humidity | ±2% between 10...90% rH @ 21 °C | |||||||||||||||||||||
| Accuracy temperature | ±0.5 °C @ 25 °C | |||||||||||||||||||||
| NTC10k Pre (10k3): ±0.2 °C @ 25 °C | ||||||||||||||||||||||
| Operating condition air flow | max. 12 m/s | |||||||||||||||||||||
| Materials | Cable gland | PA6, black | ||||||||||||||||||||
| Housing | Cover: Lexan, Belimo orange NCS S0580- Y6OR | |||||||||||||||||||||
| Bottom: Lexan, Belimo orange NCS S0580- Y6OR | ||||||||||||||||||||||
| Seal: 0467 NBR70, black |
| Scope of delivery | Mounting flange |